Patient Preparation
|
3-PLANE LOC | Calibration Scan BH | Cor SSFSE ABD | AXL SSFSE ABD | AXL T2 FSAT BH ABD | AXL IN/OUT PH ADRENALS | COR IN/OUT PH ADRENALS |
AXL 3D LAVA ABD | COR 3D LAVA ABD |
|
IMAGING PARAMETERS
|
|||||||||
|
Plane
|
3-PLANE | AXIAL | CORONAL | AXIAL | AXIAL | AXIAL | CORONAL | AXIAL | CORONAL |
|
Mode
|
2D | 2D | 2D | 2D | 2D | 2D | 2D | 3D | 3D |
|
Pulse Seq |
Gradient Echo | Gradient Echo | Spin Echo | Spin Echo | FRFSE-XL | SPGR | SPGR | LAVA | LAVA |
|
PSD Name
|
-- | -- | -- | -- | -- | -- | -- | -- | -- |
| Imaging Options | Seq Fast | Fast Calib | Fast ZIP512 SS | Fast ZIP512 SS | FC TRF Fast ZIP512 FR | EDR Fast ZIP512 | EDR Fast ZIP512 | EDR Fast ZIP2 | EDR Fast ZIP512 ZIP2 |
|
SCAN TIMING
|
|||||||||
|
# of Echoes
|
1 | 1 | 1 | 1 | 2 | 2 | 1 | 1 | |
|
TE
|
-- | -- | 180.0 | 90.0 | 100.0 | -- | -- | -- | -- |
|
TR
|
-- | -- | Minimum | Minimum | 2110.0 | 200.0 | 200.0 | -- | -- |
|
Flip Angle
|
-- | -- | -- | -- | -- | 90 | 90 | 12 | 12 |
|
Bandwidth
|
-- | -- | 31.25 | 31.25 | 31.25 | -- | -- | 62.50 | 62.50 |
|
ADDITIONAL PARAMETERS (see attached instructions)
|
|||||||||
|
SAT
|
|||||||||
|
ACQUISITION TIMING
|
|||||||||
|
Freq
|
256 | -- | 256 | 256 | 256 | 256 | 256 | 512 | 512 |
|
Phase
|
128 | -- | 192 | 192 | 160 | 160 | 160 | 160 | 160 |
|
NEX
|
1.00 | -- | -- | -- | 1.00 | 1.00 | 1.00 | -- | -- |
|
Phase FOV
|
1.00 | -- | 1.00 | 1.00 | 0.75 | 0.75 | 0.75 | 0.80 | 0.80 |
|
Locs Before Pause
|
-- | -- | 10 0 | -- | -- | -- | -- | -- | -- |
|
Freq Dir
|
Unswap | R/L | S/I | R/L | R/L | R/L | S/I | R/L | S/I |
|
Auto Center Freq
|
|||||||||
|
Auto Shim
|
Auto | Auto | Auto | Auto | Auto | Auto | Auto | Auto | Auto |
|
Contrast
|
No | No | No | No | No | No | No | No | No |
|
SCANNING RANGE
|
|||||||||
|
FOV
|
48.0 | 48.0 | 44.0 | 32.0 | 40.0 | 38.0 | 38.0 | 36.0 | 36.0 |
|
Slice Thickness
|
10.0 | 13.0 | 8.0 | 8.0 | 8.0 | 4.0 | 4.0 | 6.0 | 6.0 |
|
Spacing
|
5.0 | 0.0 | 0.0 | 2.0 | 1.0 | 0.0 | 0.0 | -- | -- |
|
Start - End
|
|||||||||
|
# of Slices
|
-- |
48 | 20 | -- | -- | -- | -- | -- | -- |
|
Scan Time
|
|||||||||
Patient Preparation:
· Start intravenous line (20 or 22 gauge iv). If iv calibre is small (i.e. 22 gauge) then pre-warm the gadolinium contrast to body temperature to reduce its viscosity.
· Oxygen, 2-4 liters/min by nasal canulae is essential if patient is short of breath
· Valium (5-10mg po) or Xanax (1-2 mg po) if patient is claustrophobic
Coil: Body coil is best because of its large field-of-view that allows imaging from diaphragm to femoral heads. If using the torso array, consider rotating 90 degrees for greater S/I coverage.
Patient Positioning: Supine, feet first,
Landmark:
Series 1:
Series 2:
Series 3:
Series 4:
Filming Instructions:
Billing Instructions:
ICD9 Codes:
Sample Normal Dictation: